• High number of cycles and low power consumption.
• Ability to operate even in the event of a power failure thanks to the central group with UPS
• Fast and easy to install thanks to the foundation box easily assembled without welding
• Equipped with RS485 communication bus and Ethernet connection via TCP / IP
• Integrated encoder and amperometric obstacle detection
• Equipped with anti-vandal function, which allows to detect a forced command, to rearm the bollard and activate an alarm
• PLUG&PLAY Connection between bollard and control panel
• EN124 (40T) Top equipped with LED lights
Product specifications: FORCE825/I
Cylinder height | 800 mm |
Cylinder diameter | 254 mm |
Raising time | 10 s |
Lowering time | 9 s |
Power Supply | 230 Vac / 50/60 Hz |
Motor supply | 24 Vdc |
Absorbed current | 8 A |
Absorbed power | 90 W |
Standby consumption | 11 W |
Consumption during rising | 1.4 A |
Daily cycles | 600 |
Impact resistance | 18.000 J |
Breakout resistance | 240.000 J |
Operating temperature | -20°C / +50°C |
Protection level | IP68 |
Electric Brake | 5 N |
Weight (without foundation box) | 155/167 kg |
|
CP1S Power supply: 230/250 Vac - 50/60 Hz - transformer with selectable voltage / Equipped with command ALL UP / ALL DOWN / 8 control inputs / 4 control inputs for loop detectors / 2 static outputs 24 V / 8-Dip switch programmable for different configurations / Diagnostic LED / Connection to Ethernet network via TCP / IP LAN / Communication between the central bollard and central CP by means of the RS485 communication bus / Embedded electronics for the management of two traffic lights (no need CP.TL control board for traffic lights) / 6 different configurations for loop detectors / Prepared for any kind of command |
|
CP1SK Power supply: 230/250 Vac - 50/60 Hz - transformer with selectable voltage / Equipped with command ALL UP / ALL DOWN / 8 control inputs / 4 control inputs for loop detectors / 2 static outputs 24 V / 8-Dip switch programmable for different configurations / Diagnostic LED / Connection to Ethernet network via TCP / IP LAN / Communication between the central bollard and central CP by means of the RS485 communication bus / Version with batteries for automatic operation during power failure / Embedded electronics for the management of two traffic lights (no need CP.TL control board for traffic lights) / 6 different configurations for loop detectors / Prepared for any kind of command |
|
CP2S Power supply: 230/250 Vac - 50/60 Hz - transformer with selectable voltage / Equipped with command ALL UP / ALL DOWN / 8 control inputs / 4 control inputs for loop detectors / 2 static outputs 24 V / 8-Dip switch programmable for different configurations / Diagnostic LED / Connection to Ethernet network via TCP / IP LAN / Communication between the central bollard and central CP by means of the RS485 communication bus / Embedded electronics for the management of two traffic lights (no need CP.TL control board for traffic lights) / 6 different configurations for loop detectors / Prepared for any kind of command |
|
CP2SK Power supply: 230/250 Vac - 50/60 Hz - transformer with selectable voltage / Equipped with command ALL UP / ALL DOWN / 8 control inputs / 4 control inputs for loop detectors / 2 static outputs 24 V / 8-Dip switch programmable for different configurations / Diagnostic LED / Connection to Ethernet network via TCP / IP LAN / Communication between the central bollard and central CP by means of the RS485 communication bus / Version with batteries for automatic operation during power failure / Embedded electronics for the management of two traffic lights (no need CP.TL control board for traffic lights) / 6 different configurations for loop detectors / Prepared for any kind of command |
|
RES Heating resistance for cold areas (accessory supplied pre-assembled). |
|
BUZZ Warning buzzer (accessory supplied pre-assembled). |
|
AUT Device that allows an automatic lowering maneuver of the bollard in case of power failure (accessory supplied pre-assembled). |
|
KTOOLS Set of installation tools. |
|
CA825A Foundation box in steel with cataphoresis treatment for FORCE 825. Quick assembly with screws. |
|
C05/10/15/20/25 Cable with connector L= 5/10/15/20/25 m. |
|
TOP25 Cover for foundation box. |