VIGILANT800/I

https://www.riseweb.it/img/product/md_99114f3ed9bda586e3429c7f2915775c/jpg/vigilant800-i-powder-steel-rise-srl.jpg VIGILANT800/I

VIGILANT800/I

24 Vdc electromechanical bollard, powder coating steel or AISI 316 electropolished stainless steel finish.


Finishing




• High number of cycles and low power consumption

• Ability to operate even in the event of a power failure thanks to the central group with UPS

• Quick and easy to install thanks to the foundation box can be assembled on site without welding

• Equipped with RS485 communication bus and Ethernet connection via TCP/IP

• Device encoder integrated obstacle detection and amperometric

• Equipped with anti-vandal function, which allows to detect a forced command, to reset the bollard and activate an alarm

• PLUG&PLAY Connection between bollard and control panel

• EN124 (40T) Top equipped with LED lights

Product specifications: VIGILANT800/I

Cylinder height800 mm
Cylinder diameter200 mm
Raising time7 s
Lowering time5 s
Power Supply230 Vac / 50/60 Hz
Motor supply24 Vdc
Absorbed current7 A
Absorbed power90 W
Standby consumption11 W
Consumption during rising1.4 A
Daily cycles1,000
Impact resistance11.000 J
Breakout resistance180.000 J
Operating temperature-20°C / +50°C
Protection levelIP68
Electric Brake5 N
Weight (without foundation box)112/120 kg
CP1S

CP1S

Power supply: 230/250 Vac - 50/60 Hz - transformer with selectable voltage / Equipped with command ALL UP / ALL DOWN / 8 control inputs / 4 control inputs for loop detectors / 2 static outputs 24 V / 8-Dip switch programmable for different configurations / Diagnostic LED / Connection to Ethernet network via TCP / IP LAN / Communication between the central bollard and central CP by means of the RS485 communication bus / Embedded electronics for the management of two traffic lights (no need CP.TL control board for traffic lights) / 6 different configurations for loop detectors / Prepared for any kind of command

CP1SK

CP1SK

Power supply: 230/250 Vac - 50/60 Hz - transformer with selectable voltage / Equipped with command ALL UP / ALL DOWN / 8 control inputs / 4 control inputs for loop detectors / 2 static outputs 24 V / 8-Dip switch programmable for different configurations / Diagnostic LED / Connection to Ethernet network via TCP / IP LAN / Communication between the central bollard and central CP by means of the RS485 communication bus / Version with batteries for automatic operation during power failure / Embedded electronics for the management of two traffic lights (no need CP.TL control board for traffic lights) / 6 different configurations for loop detectors / Prepared for any kind of command

CP2S

CP2S

Power supply: 230/250 Vac - 50/60 Hz - transformer with selectable voltage / Equipped with command ALL UP / ALL DOWN / 8 control inputs / 4 control inputs for loop detectors / 2 static outputs 24 V / 8-Dip switch programmable for different configurations / Diagnostic LED / Connection to Ethernet network via TCP / IP LAN / Communication between the central bollard and central CP by means of the RS485 communication bus / Embedded electronics for the management of two traffic lights (no need CP.TL control board for traffic lights) / 6 different configurations for loop detectors / Prepared for any kind of command

CP2SK

CP2SK

Power supply: 230/250 Vac - 50/60 Hz - transformer with selectable voltage / Equipped with command ALL UP / ALL DOWN / 8 control inputs / 4 control inputs for loop detectors / 2 static outputs 24 V / 8-Dip switch programmable for different configurations / Diagnostic LED / Connection to Ethernet network via TCP / IP LAN / Communication between the central bollard and central CP by means of the RS485 communication bus / Version with batteries for automatic operation during power failure / Embedded electronics for the management of two traffic lights (no need CP.TL control board for traffic lights) / 6 different configurations for loop detectors / Prepared for any kind of command

CP4S

CP4S

Power supply: 230/250 Vac - 50/60 Hz - transformer with selectable voltage / Equipped with command ALL UP / ALL DOWN / 8 control inputs / 4 control inputs for loop detectors / 2 static outputs 24 V / 8-Dip switch programmable for different configurations / Diagnostic LED / Connection to Ethernet network via TCP / IP LAN / Communication between the central bollard and central CP by means of the RS485 communication bus / Embedded electronics for the management of two traffic lights (no need CP.TL control board for traffic lights) / 6 different configurations for loop detectors / Prepared for any kind of command

CP4SK

CP4SK

Power supply: 230/250 Vac - 50/60 Hz - transformer with selectable voltage / Equipped with command ALL UP / ALL DOWN / 8 control inputs / 4 control inputs for loop detectors / 2 static outputs 24 V / 8-Dip switch programmable for different configurations / Diagnostic LED / Connection to Ethernet network via TCP / IP LAN / Communication between the central bollard and central CP by means of the RS485 communication bus / Version with batteries for automatic operation during power failure / Embedded electronics for the management of two traffic lights (no need CP.TL control board for traffic lights) / 6 different configurations for loop detectors / Prepared for any kind of command

RES

RES

Heating resistance for cold areas (accessory supplied pre-assembled).

BUZZ

BUZZ

Warning buzzer (accessory supplied pre-assembled).

AUT

AUT

Device that allows an automatic lowering maneuver of the bollard in case of power failure (accessory supplied pre-assembled).

KTOOLS

KTOOLS

Set of installation tools.

CA800A

CA800A

[9150004] Foundation box in steel with cataphoresis treatment for VIGILANT 800. Quick assembly with screws.

TOP20

TOP20

Cover for foundation box.

C05/10/15/20/25

C05/10/15/20/25

Cable with connector L= 5/10/15/20/25 m.

https://www.riseweb.it/images/logo.jpg Via della Tecnica, 10 - 36010 Velo d’Astico (VI) ITALY sales@riseweb.it +39 0444751401